Article source:
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Conductor
Tinned copper wires
Insulation
Low smoke halogen free flame retardant compound
Single Wrapped
Filler
Fiber Braid
Sheath
Low smoke halogen free flame retardant compound
|
Nominal Voltage | 750V |
Long-term Working Temperature | 125°C |
Lowest Operation Temperature | -25°C |
Minimum Bending Radius | 6 x Overall Diameter |
Flame Retardant | GB/T 18380.1-2001; GB/T 18380.3-2001 C |
Low Corrosivity (Acidity & Conductivity) | GB/T17650.1-1998; GB/T17650.2-1998 |
Halogen Free | GB/T17650.1-1998; GB/T17650.2-1998 |
Low Smoke | GB/T17651.1-1998; GB/T17651.2-1998 |
Number of conductor×Nominal Cross-Sectional Area |
Conductor Construction |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Maximum Conductor Resistance 20°C |
mm² | No/mm | mm | mm | mm | Ω/km |
20×3.5+56×1.25 | 20×66/0.26+56×50/0.18 | 1.0/0.8 | 3.3 | 49 | 5.38/15.5 |